﻿<?xml version="1.0" encoding="UTF-8"?>
<ArticleSet>
  <Article>
    <Journal>
      <PublisherName>Iranian Dental Association</PublisherName>
      <JournalTitle>Journal of Iranian Dental Association</JournalTitle>
      <Issn>3060-8201</Issn>
      <Volume>19</Volume>
      <Issue>1</Issue>
      <PubDate PubStatus="ppublish">
        <Year>2007</Year>
        <Month>06</Month>
        <DAY>01</DAY>
      </PubDate>
    </Journal>
    <ArticleTitle>Effect of smear layer on the retention of custom made posts luted with two different cements</ArticleTitle>
    <FirstPage>34</FirstPage>
    <LastPage>42</LastPage>
    <Language>EN</Language>
    <AuthorList>
      <Author>
        <FirstName>Hasan</FirstName>
        <LastName>Sazgara</LastName>
      </Author>
      <Author>
        <FirstName>Kaveh</FirstName>
        <LastName>Seyyedan</LastName>
      </Author>
      <Author>
        <FirstName>Amir hossein</FirstName>
        <LastName>Majidi</LastName>
      </Author>
    </AuthorList>
    <PublicationType>Journal Article</PublicationType>
    <ArticleIdList>
      <ArticleId IdType="doi">
      </ArticleId>
    </ArticleIdList>
    <History>
      <PubDate PubStatus="received">
        <Year>2007</Year>
        <Month>08</Month>
        <Day>08</Day>
      </PubDate>
      <PubDate PubStatus="accepted">
        <Year>2013</Year>
        <Month>02</Month>
        <Day>25</Day>
      </PubDate>
    </History>
    <Abstract>Effect of smear layer on the retention of custom made posts luted with two different cements Dr. H. Sazgara*- Dr. K. Seyyedan ** - Dr. A.H. Majidi*** *Associate Professor of Fixed Prosthodontics Dept., Faculty of Dentistry, Shaheed Beheshti University of Medical Sciences.**Assistant Professor of Fixed Prosthodontics Dept., Faculty of Dentistry, Shaheed Beheshti University of Medical Sciences. ***Assistant Professor of Fixed Prosthodontics Dept., Faculty of Dentistry, Qazvin University of Medical Sciences. Background and Aim: Post retention has a considerable effect on restorative treatments and is influenced by various factors. The purpose of this study was to evaluate the effect of dentinal smear layer on the retention of custom-made posts luted with composite resin and zinc phosphate cements. Materials and Methods: Forty single-rooted lower premolars were decoronated, filed and filled with gutta-percha and divided into 4 equal groups. Post spaces were prepared to a length of 8 mm. Direct post patterns were made with acrylic resin and castings were fabricated using Ni-cr alloy. In Groups A and C, the post spaces were rinsed with 2 ml of 0.9% normal saline. The specimens in Groups B and D were rinsed with 1 ml of 17% EDTA followed by 1 ml of 5.25% Naocl and 10 ml distilled water. After drying, ZPC (Dentsply) was used for cementation in groups A and B. The samples in Groups C and D were luted with Panavia F2.0. Retention was measured on a Universal Testing Machine at 0.5 m/min. Data were subjected to statistical analysis using ANOVA. Results: The mean amount of retention was 19.66Â±1.98 kg, 19.72Â±2.08 kg, 20.99Â±2.08 kg and 22.17Â±3.66 kg in groups A, B, C and D, respectively. There was no significant difference between the groups, but the mean value was highest in group D. Conclusion: The use of resin cement provided greater retention for custom-made posts compared to ZPC. Removing dentinal smear layer did not significantly affect the retention of custom-made posts cemented with ZPC or Panavia F2.0. Key words: Smear layer - Custom-made post - Resin cement - Zinc phosphate cement - Retention </Abstract>
  </Article>